Recharge to extensive aquifers by means of atmospheric chloride deposition and ground temperature

Authors

  • E. Custodio Dept. Ingeniería del Terreno, Cartográfica y Geofísica / Fundación CIHS. Universidad Politécnica de Cataluña - Real Academia de Ciencias Exactas, Físicas y Naturales

DOI:

https://doi.org/10.21701/bolgeomin.120.4.010

Keywords:

aquifer, chloride balance, geothermal gradient, recharge, Spain

Abstract


One of the most uncertain and at the same time essential values for groundwater knowledge and management is aquifer recharge, especially in large areas with scarce data. Under steady state circumstances the atmospheric chloride deposition balance is an effective method to estimate average diffuse recharge and its possible error. Progress in the application are reported to some aquifers, in some of which the water mixtures in groundwater sampling from the aquifer due to recharge spatial variability are considered. Also, recharge affects in ground temperature distribution is considered as an indicator of recharge. Spanish examples from the Iberian Peninsula: Doñana, Anoia, the Llobregat delta, and the whole territory are considered, and also from the archipelagos The Canaries: Gran Canaria, Fuerteventura and La Gomera, and the Balearic Islands: Mallorca.

Downloads

Download data is not yet available.

References

Alcalá, F.J. 2006. Recarga a los acuíferos españoles mediante balance hidrogeoquímico. Tesis doctoral, Universitat Politècnica de Catalunya (UPC). Barcelona. 2 Vols, 1-719.

Alcalá, F.J. and Custodio, E. 2008a. Atmospheric chloride deposition in continental Spain. Hydrological Processes, 22(98), 3636-3650. https://doi.org/10.1002/hyp.6965

Bredehoeft, J.D. and Papadopulos, I.S. 1965. Rates of vertical groundwater movement estimated from the Earth's termal profile. Water Resources Research, 15, 1616-1622.

Cartwright, K. 1979. Measurement of fluid velocity using temperature profiles: experimental verification. Journal of Hydrology, 43, 185-194. https://doi.org/10.1016/S0167-5648(09)70017-6

Custodio, E. 2007. Acuíferos detríticos costeros del litoral mediterráneo peninsular: valle bajo y delta del Llobregat. Enseñanza de las Ciencias de la Tierra: Las Aguas Subterráneas. Rev. Asoc. Esp. Enseñanza de las Ciencias de la Tierra. Madrid, 15(3), 295-304.

Custodio, E. 2009. Estimation of aquifer recharge by means of atmospheric chloride deposition balance in the soil. Contributions to Science I, 5(2) (en prensa).

Custodio, E. y Llamas, M.R. (eds) 1976/1983. Hidrología subterránea. Ediciones Omega. Barcelona, 3 Vols, 1-2350.

Custodio, E. et al. 1996. Análisis térmico preliminar de los acuíferos en Doñana. Actas IV Simposio del Agua en Andalucía (IV - SIAGA). II, 57-87.

Custodio, E. et al. (eds) 1997. La evaluación de la recarga a los acuíferos en la Planificación Hidrológica. Assoc. Intern. Hidrogeólogos-Grupo Español. Instituto Geológico y Minero de España, Madrid, 1-455.

De Haro, J.M. et al. 2000. Variación temporal de la recarga al acuífero freático del Parque Natural de Doñana, Huelva. Boletín Geológico y Minero, 111(1), 77-88.

De Vries, J.J. and Simmers, I. 2002. Groundwater recharge, an overview of processes and challenges. Hydrogeology Journal, 10, 5-17. https://doi.org/10.1007/s10040-001-0171-7

Eriksson, E. and Khunakasem, V. 1969. Chloride concentrations in groundwater, recharge rate and rate of deposition of chloride in the Israel coastal plain. Journal of Hydrology, 7(2), 178-197. https://doi.org/10.1016/0022-1694(69)90055-9

Iglesias, M. et al. 1996. Caracterización química de la lluvia y estimación de la recarga en el area de El Abalario, Doñana, Huelva. Actas del III Simposio del Agua en Andalucía. Almería. II, 99-121.

Lerner, D.N. et al. 1990. Groundwater recharge: A guide to understanding and estimating natural recharge. International Contributions to Hydrogeology. Intern. Assoc. Hydrogeologists. Vol: 8. Heise. Hannover, 1-345.

López, J.J. y Giráldez, J.V. 1999. Estimación de la recarga mediante un método de balance de agua en el suelo desnudo del Parque Natural del entorno de Doñana. Ingeniería del Agua, 6(1), 37-48. https://doi.org/10.4995/ia.1999.2775

Scanlon, B.R. et al. 2002. Choosing appropriate techniques for quantifying groundwater recharge. Hydrogeology Journal, 10(1), 18-39. https://doi.org/10.1007/s10040-001-0176-2

Simmers, I. et al. 1997. Recharge of phreatic aquifers in (semi)arid areas. Contributions to Hydrogeology 19, Intern. Assoc. Hydrogeologists. Balkema, 1-277.

Trick, T. 1998. Impactos de las extracciones de aguas subterránea en Doñana: aplicación de un modelo numérico con consideración de la variabilidad de la recarga. Tesis Doctoral. Universidad Politécnica de Cataluña. Barcelona.

Trick, T. and Custodio, E. 2004. Hydrodynamic characteristics of the western Doñana region (area of El Abalario), Huelva, Spain. Hydrogeology Journal, 12(3), 321-335. https://doi.org/10.1007/s10040-003-0282-4

Downloads

Published

2009-12-30

How to Cite

Custodio, E. (2009). Recharge to extensive aquifers by means of atmospheric chloride deposition and ground temperature. Boletín Geológico Y Minero, 120(4), 631–640. https://doi.org/10.21701/bolgeomin.120.4.010

Issue

Section

Articles